Centrifuge 5702/ 5702 R/5702 RH

Do I need IVD?
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH
Centrifuge 5702/ 5702 R/5702 RH

The 5702 family of low speed, general purpose centrifuges was especially designed to meet the requirement of low- to mid-throughput clinical research and cell culture labs. They are compact in design so that one can fit comfortably on every lab bench, quiet in operation to benefit your work environment. More information

Order Info
show more (3)

Product Information

The 5702 family of low speed, general purpose centrifuges was especially designed to meet the requirement of low- to mid-throughput research and cell culture labs. They are compact in design so that one can fit comfortably on every lab bench, quiet in operation to benefit your work environment, and provide 6 different rotor options to accommodate any type of tube.

The right model for your application:



› Centrifuge 5702 for standard applications
› Refrigerated Centrifuge 5702 R for heat sensitive samples
› Heated and refrigerated Centrifuge 5702 RH allows centrifugation under biological conditions to improve cell viability for more accurate results in downstream applications (e.g. cell cultivation)

Ergonomics


› Very compact footprint to fit on every lab bench
› Very quiet operation to benefit your environment
› Low access height for simple loading and unloading of samples

Centrifuge 5702/ 5702 R/5702 RH

Temperature management


› Optimizes air flow minimizes sample warming during run (5702)
› FastTemp function for fast precooling (5702 R/RH)
› Active heating guarantees high temperature accuracy during the entire centrifugation cycle (only 5702 RH)
› ECO shut-off engages after 8 hours of nonuse to reduce energy consumption and extend compressor life (5702 R/RH)

Centrifuge 5702/ 5702 R/5702 RH

Quality and safety


› Stainless steel rotor chamber is rust-free and easy to clean
› Imbalance detection for maximum safety
› Key lock to prevent accidental parameter changes
› Aerosol-tight caps for safe centrifugation of hazardous samples optionally available

Centrifuge 5702/ 5702 R/5702 RH

Features

  • Max. speed: 3,000 × g (4,400 rpm)
  • Very compact footprint to fit on every lab bench
  • Very quiet operation to benefit your environment
  • Low access height for simple loading and unloading of samples
  • SOFT brake function for slow acceleration and braking. Optimized for cell separation by gradient centrifugation
  • “At set RPM” function starts the timer when the selected rotational speed is reached for reproducible centrifugation runs
  • Key lock to prevent unintentional adjustments
  • Stainless steel rotor chamber is rust-free and easy to clean
  • Electronic imbalance detection for maximum safety

Applications

  • Centrifuge 5702 for standard applications
  • Refrigerated Centrifuge 5702 R for heat sensitive samples
  • Heated and refrigerated Centrifuge 5702 RH allows centrifugation to improve cell viability for more accurate results in downstream applications

Special features for Centrifuge 5702 R and Centrifuge 5702 RH

  • Temperature settings from -9 °C to 40 °C
  • FastTemp function for fast precooling
  • Continuous cooling maintains a constant temperature after the run has been completed – your samples stay cool
  • ECO shut-off engages after 8 hours of non-use to reduce energy consumption and extend compressor life
  • Two program keys to store routine programs
  • Active heating guarantees high temperature accuracy during the entire centrifugation cycle (only 5702 RH)
 57025702 R5702 RH
Max. RCF3,000 × g3,000 × g3,000 × g
Speed100 – 4,400 rpm (100 rpm steps)100 – 4,400 rpm (100 rpm steps)100 – 4,400 rpm (100 rpm steps)
Max. capacity4 × 100 mL4 × 100 mL4 × 100 mL
Rotors available666
Acceleration time1≤19 s≤20 s≤19 s
Deceleration time1≤19 s≤28 s≤29 s
DisplayLCDLCDLCD
Timer0 – 99 min, with continuous run function0 – 99 min, with continuous run function0 – 99 min, with continuous run function
SOFT brake functionyesyesyes
Noise level< 52 dB(A) with Rotor A-4-38<46 dB(A) with Rotor A-4-38<46 dB(A) with Rotor A-4-38
Volume range400 mL400 mL400 mL
Power supply230 V, 50 – 60 Hz230 V, 50 – 60 Hz230 V, 50 – 60 Hz
Max. power consumption200 W380 W380 W
Dimensions (W × D × H)32 × 40 × 24 cm38 × 58 × 26 cm38 × 58 × 26 cm
Height (with open lid)53 cm60 cm60 cm
Weight w/o accessories20 kg36 kg36 kg
Coolingnon-refrigeratedrefrigeratedrefrigerated/heated
Temperature control range-9 °C to 40 °C-9 °C to 42 °C
1Acceleration and deceleration times may vary depending on rotor, load and voltage version.