CryoCube® F101h

New
Image – CryoCube<sup>&reg;</sup> F101h, ULT freezer, 100 L, Eppendorf
New
Image – Air Vent port of ULT lab freezer
New
Image – CryoCube<sup>&reg;</sup> F101h
New
Image – CryoCube<sup>&reg;</sup> F101h
New
Image – CryoCube<sup>&reg;</sup> F101h
New
Image – CryoCube<sup>&reg;</sup> F101h
New
Image – CryoCube<sup>&reg;</sup> F101h
New
Image – CryoCube F101h lab scene, open F101h
New
Image – CryoCube F101h display settings
New
Image – CryoCube F101h with person scanning tube for documentation and finally storage
New
Image – CryoCube F101h Person pulling out rack
Image – CryoCube<sup>&reg;</sup> F101h, ULT freezer, 100 L, Eppendorf
Image – Air Vent port of ULT lab freezer
Image – CryoCube<sup>&reg;</sup> F101h
Image – CryoCube<sup>&reg;</sup> F101h
Image – CryoCube<sup>&reg;</sup> F101h
Image – CryoCube<sup>&reg;</sup> F101h
Image – CryoCube<sup>&reg;</sup> F101h
Image – CryoCube F101h lab scene, open F101h
Image – CryoCube F101h display settings
Image – CryoCube F101h with person scanning tube for documentation and finally storage
Image – CryoCube F101h Person pulling out rack

Looking for a personal under-the-bench ULT freezer?
The Eppendorf CryoCube F101h ultra-low temperature (ULT) freezer combines compact design with real -80 °C to offer long-lasting and reliable ULT technology for safe sample storage. More information

Order Info

Product Information

When it comes to maximizing sample storage capacity at the bench, the Eppendorf CryoCube F101h freezer sets the standard: Up to 6,000 vessels below your bench in the lab. By taking advantage of ultra-efficient, compact vacuum insulation panels which are used in combination with traditional PU foam insulation, we slim down the freezer wall thickness from 130 mm to 80 mm.
The footprint is limited to half a square meter, especially designed for small labs. The CryoCube F101h is stackable as an option. The temperature range for this -80°C lab freezer is between -50 °C and -86 °C.

Cost of ownership
When investing in a new ULT freezer, the product price itself is only one aspect. Others include the long-term costs of power consumption and the costs of service and spare parts. Keep in mind, a high-quality ULT freezer will do its job in the lab for 10 years or more.

CryoCube® F101h

How much effort did you spend on your sample?
Did you ever calculate the value of the contents of your freezer? All the hours, days, weeks, and months spent on your samples? More than 50,000 samples fit into large, standard ULTs. The value of every single sample differs – from simple buffers to high-value cell extracts, expensive enzymes, or very rare sample material. Assuming an average value of 10 euros per vial, the total value already reaches 500,000 euros.
When predominantly storing high-value samples which are a result of months of work – you reach a value in your freezer far beyond half a million euros.

Your new ULT freezer is not limited to being a storage room for samples. This instrument is your assurance for long-term scientific success, it guards the results of your work.

Eppendorf ULT freezers are equipped with reliable heavy-duty compressors (2-stage cascade cooling system). Quick pull-down times enable fast re-use after cleaning/defrosting of the instrument. The freezers have short recovery times back to -80 °C after opening to provide extra sample safety. Their temperature range is from -50 °C to -86 °C. For even higher sample safety, the Eppendorf ULT freezers can be equipped with CO2/LN2 back-up systems and a chart recorder. Temperature monitor systems can be used to monitor the freezers remotely.

CryoCube® F101h

Burdened by unsorted boxes cluttering your freezer?
Make your scientific life easier: Store your freezer storage boxes within organized freezer racks. The CryoCube F101h can be equipped with a broad range of different racks made of stainless steel as well as of aluminum. Take advantage of the online Eppendorf rack configuration tool (please use Mozilla FireFox as browser): Rack configuration tool
For other racking systems, please check the inner dimensions of the freezer and contact Eppendorf.

Additionally, you might think about a sample management solution beyond sample location documentation by paper or spreadsheet.
Start a 30-day free trial of our sample management software eLABInventory:
www.eLABInventory.com

CryoCube® F101h

Annoyed by uncomfortable handling?
Ergonomics is far beyond the »ergonomically designed chair«. Eppendorf already started to optimize the ergonomics of laboratory devices in the early 1970s.
In 2003, we started the PhysioCare Concept, focusing on ergonomic liquid handling devices like our pipettes.
Nowadays, the Eppendorf PhysioCare Concept has been extended to include additional laboratory products as a holistic solution to harmonize the workflow in your laboratory with your health and well-being. Examples for the Eppendorf ULT freezer include:
› Intuitive interface for easy handling
› Vent port for easy re-access to samples
› Low noise level for convenient working conditions
› Ergonomic door handle for easy opening and closing
› All cable interfaces are located at one corner for convenient access

Further information about the Eppendorf PhysioCare Concept:
www.eppendorf.com/physiocare/

CryoCube® F101h

Support the epGreen initiative with your Eppendorf ULT freezer



Sustainability
Sustainability for ULT freezers is a challenge: Maintaining extremely low temperatures of -86 °C for 24 hours a day, 7 days a week needs energy.
By following the epGreen concept, the Eppendorf freezer R&D team developed intelligent solutions where energy savings are combined with durable long-lasting product quality and ergonomic aspects. This future-oriented instrument class provides consumption levels which are ahead of most competitors within this volume class.
Eppendorf ULT freezers are among the most energy-efficient in the industry, reducing energy consumption by thousands of kilowatt hours over our competition.

CryoCube® F101h

Factors influencing the energy consumption
› Thickness of insulation
› Type of insulation
› Type of cooling liquid
› Efficiency of compressors
› Control of compressor
› Pressure in cooling system
› Style of cooling loops (diameter, length, density,..)
› Sealings of outer door
› Sealings of inner doors
› Insulation of inner doors
› Insulatioon of outer door

CryoCube® F101h

Our part for sustainability of ULT freezers
› Production moved into new building with state-of-the-art insulation to save heating energy and power
› Heat output during final individual unit testing discharges building heating system
› Plastic and cardboard compactors introduced and waste rebate system in place
› Local requirements for waste management (collection of electronic waste like circuit boards, recycling via authorized recycling organizations) and internal guide lines
› Usage of green cooling liquids in Eppendorf ULT freezers for 10 years
› Packaging parts have increasing share of recycled origin
› Packaging is more than 99 % recyclable (wood, cardboard, PE-foil)
› REACH + RoHS compliant
› ENERGY STAR® partner
› Marketing material is printed on FSC certified paper, wherever possible focus on pdf only
› Shipment by cargo ship to reduce CO2 footprint

CryoCube® F101h

Hydrocarbons
In 2014, the European Union announced a ban of all non-hydrocarbon-liquids (EU_517/2014) until 2020 (also known as "F-gas regulation").
Hydrocarbons are also known as green or natural gases. The two major representatives are propane and ethane (known as R290 and R170). Based on IEC 60335-2-89, no additional safety instructions for using green gases in ULT freezers are necessary.
This ban includes all cooling devices except instruments for temperatures below -50 °C. Based on this exception, ULT freezers of -86 °C can continue to run with HFCs. Still, it makes sense to replace the HFC cooling liquids also for ULTs as global warming needs to be slowed down.
Due to this goal, we at Eppendorf clearly plan to replace all classic cooling ULT freezers within the next years.

CryoCube® F101h

Remember 2008?
As one of the very first movers for green gases at -86°C, Eppendorf has now 10 years of experience in R&D, production, logistics, and service in the field.
In 2008, the (Eppendorf) New Brunswick Premium U570h was one of the very first commercially available ULT freezers driven by green cooling liquids.

Safety assessment for green gases:
Based on IEC 60335-2-89, there are no additional required safety instructions for using natural gases in ULT freezers as long as the cooling liquid loops are hermetically sealed and the amount per cooling liquid is limited to 150 g. All Eppendorf ULT freezers using green gases fulfill these conditions for safe usage.

CryoCube® F101h

Pit stop needed?
Taking care of your freezer can help ensure optimal storage of your samples for years to come.
In addition to our extensive standard warranty, Eppendorf offers ULT Freezer Performance Plans to suit your lab’s needs while enhancing your peace of mind. You can choose between essential function checks, preventive maintenance plans, or Installation and Operational (IQ/OQ) certification services. Protect your priceless samples!

CryoCube® F101h

Lost in samples? Stay organized!
Over many years, you collect hundreds and thousands of samples – samples that are the results of years of hard work – samples of high value. When storing these, it is vital to keep them safe and accessible.
Many scientists still use spreadsheets or even paper-based lists to keep track of their storage. While these solutions may work most of the time, they are susceptible to human error, damage, and misplacement.
Keep track of your samples with eLABInventory
eLABInventory is a sample management software.

Start a free 30-day trial!
Visit www.eLABInventory.com

CryoCube® F101h

Struggling with paper-based documentation?
The eLABJournal Electronic Lab Notebook offers an intuitive and flexible solution to document research and track research data like workflow processes where the ULT freezer is involved. Improve efficiency when documenting, organizing, searching, and archiving collected data. With the free eLABJournal add-ons, you can extend the functionality of eLABJournal to a fully integrated Laboratory Information Management System.

Start a free 30-day trial!
Visit www.eLABJournal.com

CryoCube® F101h

Features

  • Vacuum insulation panels allow for increased internal capacity with the same footprint as traditionally foamed freezers
  • Inner doors are gasketed as well as insulated creating 2 separate compartments minimizing cold air loss while you access your samples
  • Easy-to-read LED control panel and alarm status
  • Special vacuum vent with plunger ergonomically located to gain immediate access to your freezer
  • Inner doors can be quickly removed without the need for tools for easier and faster defrosting
  • Full stainless steel interior for easy cleaning during maintenance and defrost cycles; powder-coated steel exterior
  • Special low-temperature outer door seals allow gaskets to remain flexible at –86 °C and prevent ice buildup for easy access to samples
  • Password protection of alarm and temperature setpoints to prevent unauthorized setting changes

Applications

  • ULT freezers are suitable for storage and preservation of all types of biological materials/samples:
  • › Bacteria
  • › Cells
  • › Spores
  • › Pollens
  • › Protozoa
  • › Blood components
  • › DNA
  • › Tissue used in research only
  • › Preservation of chemicals or material testing components for a longer period of time
 CryoCube® F101h
Cooling liquidR290 / R170
Cooling typeair-cooled
Heat output263 W
InsulationVacuum insulation paneling / polyurethane foam
Capacity101 L
Capacity (ft3)3.6 ft³
No. of internal doors2
No. of compartments2
Max. racks per freezer6
Displayclassic
Noise level55
High-Efficiencyyes
Power supply230 V, 50 Hz
Max. power consumption6300 W
Footprint (WxD)90 x 56.6 cm
Temperature range-50 °C to -86 °C
Access port2
Pull-down time to -80 °C140 min 1
Box capacity per freezer 
53 mm (2 in) tall boxes60
64 mm (2.5 in) tall boxes48
76 mm (3 in) tall boxes36
89 mm (3.5 in) tall boxes24
102 mm (4 in) tall boxes24
127 mm (5 in) tall boxes24
Box capacity per rack 
53 mm (2 in) tall boxes10
64 mm (2.5 in) tall boxes8
76 mm (3 in) tall boxes6
89 mm (3.5 in) tall boxes4
102 mm (4 in) tall boxes4
127 mm (5 in) tall boxes4
1Empty freezer with shelves fitted, upright freezers only, pull down from 21 – 23 °C ambient conditions.

You might also consider